We regularly inspect buildings and identify many deficiencies with sprinkler systems. The inspection, testing and maintenance typically is left to the building owner.įrom my experience, this is where the process is most lacking. While local jurisdictions require fire protection professionals to be involved in the design and installation process, this is enforced through the permitting process.
![when is fire sprinkler system design not required when is fire sprinkler system design not required](https://demo.dokumen.tips/img/380x512/reader022/reader/2020060116/5e7a525152967a516430b89e/r-2.jpg)
The IFC goes on to require that NFPA 25 Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems be used to keep an automatic sprinkler system in good working order.Īs a fire protection engineer, I have participated in all phases of automatic sprinkler system design, installation, inspection, testing, and maintenance.
#When is fire sprinkler system design not required code
According to the International Fire Code (IFC) 2015 Edition, 901.6 Inspection, Testing and Maintenance, the fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents must be maintained in an operative condition at all times and shall be replaced or repaired where defective. Once a sprinkler system has been successfully installed, the responsibility of maintaining it falls to the building owner. When the design changes or unforeseen interferences arise, the contractor and designer must come up with solutions that meet the code requirements.
#When is fire sprinkler system design not required install
In addition to a properly designed sprinkler system, the sprinkler contractor must install the sprinkler system in accordance with the design. Sprinkler systems must be designed properly in accordance with the local building code and NFPA 13 Standard for the Installation of Sprinkler Systems.
![when is fire sprinkler system design not required when is fire sprinkler system design not required](https://i.pinimg.com/originals/5b/a6/4c/5ba64cde9e418768e01da9fcb4ac799d.png)
If the sprinkler system has not been designed, installed and maintained properly, the fire can spread, increasing the risk of damage to the building and harm to occupants. These systems are designed to limit the spread of a fire and contain it to the compartment of origin.īut in many facilities, problems can arise. Automatic sprinkler systems play an important part in the safety of the occupants of institutional and commercial facilities.